Search

COAXIAL CABLES RG11FC (75 Ohm) CATV SYSTEMS

Qty
Compare

In Stock

RG Ref. RG 11
Class CPR acc. to UE 305/2011 (DoP) Fca
Availability on demand
acc. to Standard EN 50117-2-3
Reaction to Fire EN50575
CONSTRUCTION DATA
Inner Conductor Ø mm 1,63
material FeCu
Dielectric Ø mm 7,20
material PEG
Film Foil Laminate material APAS
Braid material Al
Braid Optical Coverage % 65
Diameter over Braid Ø mm 8,01
Outer Sheath Ø mm 10,1
material PE
PHYSICAL DATA
Cable Weight kg/km 73,7
Min bending radius x 1/n mm 100
Max.Tensile Strength N 800
ELECTRICAL DATA
Impedance Ohm 75±2
Capacitance (@1kHz) pF/m 53 ± 2
Velocity Ratio % 85
Attenuation (at 20°C )
at 5 MHz dB/100m 1,1
at 10 MHz dB/100m 1,5
at 30 MHz dB/100m 2,2
at 50 MHz dB/100m 2,8
at 200 MHz dB/100m 5,6
at 300 MHz dB/100m 6,9
at 470 MHz dB/100m 8,8
at 862 MHz dB/100m 12,3
at 1000 MHz dB/100m 13,2
at 1750 MHz dB/100m 18,5
at 2150 MHz dB/100m 20,8
at 2400 MHz dB/100m 22,2
at 3000 MHz dB/100m 25,3
Structural return loss (SRL)
at 5 – 470 MHz dB >30
at 470 – 1000 MHz dB >28
at 1000 – 2000 MHz dB >23
at 2000 – 3000 MHz dB >20
Transfer Impedance (Zt) Class B
5 – 30 MHz mOhm/m < 15
Screening Attenuation (SA) Class A
at 30 – 1000 MHz dB >85
at 1000 – 2000 MHz dB >85
at 2000 – 3000 MHz dB >85
DC Conductor Resistance inner/outer Ohm/km 37,5 / 11,5
Loop resistance Ohm/km 49,0
Sheat Insulation voltage (spark test) kV 8,0