SKU:DG 163 ZH

In Stock

G Ref. RG 11
Class CPR acc. to UE 305/2011 (DoP) Dca s2,d2,a1
Availability on demand
Application DOCSIS 3.1 (Data Over Coax System)
acc. to Standard EN 50117-2-3
Reaction to Fire EN 50399
EN50575
CONSTRUCTION DATA
Inner Conductor Ø mm 1,63
material Cu
Dielectric Ø mm 7,20
material PEG
Film Foil Laminate material APAS
Braid material CuSn
Braid Optical Coverage % 78
Diameter over Braid Ø mm 7,85
Outer Sheath Ø mm 10,1
material LSZH
PHYSICAL DATA
Copper Content kg/km 39,5
Cable Weight kg/km 105,4
Min bending radius x 1/n mm 100
Max.Tensile Strength N 300
ELECTRICAL DATA
Impedance Ohm 75±2@200 MHz
Capacitance (@1kHz) pF/m 52 ± 2
Velocity Ratio % 85
Attenuation (at 20°C )
at 5 MHz dB/100m 1,1
at 10 MHz dB/100m 1,5
at 30 MHz dB/100m 2,2
at 50 MHz dB/100m 2,8
at 200 MHz dB/100m 5,6
at 300 MHz dB/100m 6,9
at 470 MHz dB/100m 8,8
at 862 MHz dB/100m 12,3
at 1000 MHz dB/100m 13,2
at 1750 MHz dB/100m 17,9
at 2150 MHz dB/100m 20,1
at 2400 MHz dB/100m 21,6
at 3000 MHz dB/100m 24,8
Structural return loss (SRL)
at 5 – 470 MHz dB >30
at 470 – 1000 MHz dB >28
at 1000 – 2000 MHz dB >23
at 2000 – 3000 MHz dB >20
Transfer Impedance (Zt) Class A
5 – 30 MHz mOhm/m <
Screening Attenuation (SA) Class A+
at 30 – 1000 MHz dB >95
at 1000 – 2000 MHz dB >95
at 2000 – 3000 MHz dB >85
DC Conductor Resistance inner/outer Ohm/km 8,5 / 7,5
Loop resistance Ohm/km 16,0
Sheat Insulation voltage (spark test) kV 5,0

 